Share to:
Type: Body Temperature
Brand: MCD
SKU: MCD-YT100
Quantity:
Thermal Imaging Equipment
The main features of the thermal imaging systems focus on the following:
-No touching body temperature measuring
-Group people pass without stop
-Sound and light alarm for high temperature person
-Data management system to have records
-High accuracy measuring with real time numbers of temperatures.
-Self setting of the alarm temperature.
-Easy operation for any junior operators.
-Easy movement and installations for any public places
Thermal imaging equipment series products are a set of "intelligent thermal imaging thermometer" that was developed based on years of research and development experience, customers' actual needs and market requirements. Which can quickly check and warn people with fever symptoms in the crowd, accurately display the maximum temperature value, and complete the test of the system.
1.Product introduction
1.1 Outward appearance of the equipment system
1. Non contact full range human body temperature measurement: uncooled full real-time high-sensitivity thermal imaging, long-distance non-contact temperature measurement of human body surface temperature.
2. High temperature measurement frame rate: frame rate up to 25Hz, close to real-time imaging by naked eye observation.
3. Temperature measurement accuracy: ± 0.5℃.
4. Temperature range: the temperature range of the system is 32 ~ 45 ℃.
5. Multi targets automatic measurement: the system provides real-time dynamic thermal image, which can realize multi-target automatic measurement, fast and accurate.
6. High definition face acquisition: high definition 200 W pixel network camera is used to collect high-definition face images.
7. Automatic face matching: automatic matching of visible light face photos and infrared face to facilitate eye recognition and tracing.
8. Real time record: real time record through person temperature, suspected fever automatic warning.
9. Face retrieval: it can be connected with the superior platform to realize face retrieval, face database and snapshot database, track the moving track of personnel, especially the activity track of suspected fever personnel, and quickly locate.
10. Statistical analysis: it can be connected with the superior platform to display the global control and macro analysis of the data of passers-by, passers-by and abnormal temperature people.
11. HD display: 1080p HD HDMI output to HD display screen.
12. TV stand: moveable trolley floor TV stand, easy to use.
13. Monitor height is adjustable by adjust the TV stand to meet your different viewing height.
System parts list:
No | Name | Q’ty | Unit | Note | |
1 | Front end acquisition module | IR temperature measure module | 1 | pcs | |
visible light module | 1 | pcs | 200MP | ||
Built in main board | 1 | pcs | 4core ARM main board | ||
2 | Adaptor | 1 | pcs | 12V/3A | |
3 | HDMI Output cable | 1 | pcs | ||
4 | Monitor(1080P) | 1 | pcs | ||
5 | moveable trolley floor TV stand | 1 | pcs |
Interface description
The equipment is installed on the mobile cart floor TV stand. After the equipment is fixed with the mobile cart floor TV stand, connect the power cable to the power interface, and connect it with monitor by HDMI cable. Open on it and enter the thermal imaging test interface after about 20 seconds. USB port can be used for external U disk or mouse. (As follow picture)
2. Operation Instructions
After powered on, the thermal imaging software will be automatically turned on, and the interface is as follows. At this time, the camera direction can be aimed at the channel port to be tested, and the equipment will automatically capture the photos of the normal and suspected person.
Click the thermal imaging interface with the left mouse button, and the following parameter box will display.
Temperature compensation: User can manually add or subtract a certain temperature value to make the temperature measurement value of thermal imaging more accurate.
Voice mode: There are three broadcast modes: simple mode, voice mode and silent mode. Among them, the simple mode only has voice prompt. The voice mode will has voice broadcast prompt. The silent mode normal through without broadcast, abnormal situation will alarm.
Face calibration: Face calibration is required. First, set the face switch to on. Then, a person needs to stand about 1.5 meters in front of the camera. Then, you can click the up, down, left and right buttons to move the right thermal imaging face frame to the person's face to complete the calibration.
Click “More” to enter into other parameter debugging interface.
Temperature selection: user can choose degrees Celsius or Fahrenheit according to their requirement(Default Celsius for domestic users.)
Pseudo color style: The software provides 12 kinds of pseudo color for users to choose, users can choose pseudo color display according to their preferences. The default is style 1.
Alarm temperature: The user can set the threshold of alarm temperature according to his actual situation, and the default is 37.3 ℃.
Temperature measurement mode: When the background heat source of thermal imaging is high temperature, the user can select the high temperature mode. At this time, the equipment will start the intelligent algorithm to automatically filter the influence of background high temperature heat source on the temperature measurement accuracy.
Other parameter settings: The user needs to modify the parameters under the guidance of the manufacturer's technical personnel. Under normal condition, the user is not allowed to modify the relevant parameters by himself.
First of all, the equipment needs to be connected to the Internet. The user can use the network cable to connect the equipment network port or enter the equipment system interface to connect to WiFi. When the equipment is connected to the Internet successfully, the user can enter the parameter setting interface of the software and enter more settings. The new version is detected at the bottom. Then click this upgrade indicate button. Follow the upgrade indicate is ok.
After using the equipment for a period of time, the system may slow down due to a large number of photos saved. At this time, you can enter the software parameter setting interface to set more kinds of settings. You can find the delete file button to delete all the photo data except today.
This equipment supports Chinese and English versions. When exchange languages, please go back to the system menu and select Settings > language > English to exchange to English.
The default path of photo folder is Explorer - int - normal / abnormal. The equipment supports saving records directly to the folder under the USB flash disk. After the user inserts the USB flash disk into the equipment, the default path of the photos is changed to the normal and abnormal folders on the USB flash disk. The format of USB flash disk used by users should be FAT32 format. It is better to use SanDisk or Kingston USB flash disk.
This equipment supports networking function. You need to ask for relevant software and install videos from technicians.
Save the file that named logo.png 400 * 120 in the desktop - Explorer - internal memory file, and the logo will be displayed in the upper left corner of the interface.
3. Cautions
1) Please let qualified service person or system installation person to install the equipment.
2) Install this equipment under the environment with lightning protection measures.
3) Please do not touch the lens to prevent the lens from being damaged or dirty.
4) Please pay attention to prevent the lens from being worn, scratched or even scratched.
5) Because the uncooled infrared thermal imager uses a very sensitive thermal sensor, the lens should not be directly aimed at the strong radiation source (such as the sun, laser beam direct or reflection, etc.) under any circumstances (power on or power off), otherwise it will cause permanent damage to the uncooled infrared thermal imager.
6) This product is a precise electronic equipment, so please handle it carefully in the process of use, storage and transportation to prevent the equipment from being collided by external force or falling from height.
7) During transportation and storage, the ambient temperature shall not be lower than - 25 ℃; The original packing box must be used during transportation.
8) Before turning on the equipment, make sure the power connection is correct. If the power connection is wrong, the equipment may be damaged.
9) Don't put any object on the power line, and don't put this equipment in the place where the power line is easy to touch.